Search results

Search for "software" in Full Text gives 474 result(s) in Beilstein Journal of Organic Chemistry. Showing first 200.

The ethoxycarbonyl group as both activating and protective group in N-acyl-Pictet–Spengler reactions using methoxystyrenes. A short approach to racemic 1-benzyltetrahydroisoquinoline alkaloids

  • Marco Keller,
  • Karl Sauvageot-Witzku,
  • Franz Geisslinger,
  • Nicole Urban,
  • Michael Schaefer,
  • Karin Bartel and
  • Franz Bracher

Beilstein J. Org. Chem. 2021, 17, 2716–2725, doi:10.3762/bjoc.17.183

Graphical Abstract
  • ). Multiplicity is defined as s = singlet, d = doublet, t = triplet, q = quartet, p = pentet, m = multiplet. NMR spectra were analyzed with NMR software MestReNova, version 14.2.0-26256 (Mestrelab Research S.L.). High-resolution mass spectra were performed by the LMU Mass Spectrometry Service applying a Thermo
  • dispensed into black pigmented, clear-bottom 384-well plates (Greiner, Germany). Then, plates were mounted on the FLIPR, fluo-4 was excited by LED array and emitted light was imaged through a 515 nm long pass filter with a Zyla 5.5 camera (Andor, Belfast, UK) under control of the Micromanager software
  • intensities in each single well was calculated with ImageJ software, corrected for the respective background signals and normalized to the initial fluorescence intensities (F/F0). Concentration–response curves were generated by fitting the data to a four-parameter Hill equation (Emin, Emax, EC50/IC50, and
PDF
Album
Supp Info
Full Research Paper
Published 05 Nov 2021

In-depth characterization of self-healing polymers based on π–π interactions

  • Josefine Meurer,
  • Julian Hniopek,
  • Johannes Ahner,
  • Michael Schmitt,
  • Jürgen Popp,
  • Stefan Zechel,
  • Kalina Peneva and
  • Martin D. Hager

Beilstein J. Org. Chem. 2021, 17, 2496–2504, doi:10.3762/bjoc.17.166

Graphical Abstract
  • - software was used. The temperature sweeps (DMTA) and frequency sweeps (FS) were measured with a plate-plate setup (D-PP15-SN0). The sample was heated to 150 °C and the sample gap was set to 1 mm. For the DMTA, the samples were cooled to 25 °C and heated up to 200 °C with a heating rate of 2 °C/min under a
PDF
Album
Supp Info
Full Research Paper
Published 29 Sep 2021

Exfoliated black phosphorous-mediated CuAAC chemistry for organic and macromolecular synthesis under white LED and near-IR irradiation

  • Azra Kocaarslan,
  • Zafer Eroglu,
  • Önder Metin and
  • Yusuf Yagci

Beilstein J. Org. Chem. 2021, 17, 2477–2487, doi:10.3762/bjoc.17.164

Graphical Abstract
  • detector was calibrated with polystyrene standards having narrow molecular-weight distributions. The data were analyzed using Eco-SEC analysis software. A Hitachi HT7700 (TEM) with EXALENS (120 kV) working at a high-resolution (HR) mode was used to obtain transmission electron microscopy (TEM) images, high
PDF
Album
Supp Info
Full Research Paper
Published 23 Sep 2021

Nomimicins B–D, new tetronate-class polyketides from a marine-derived actinomycete of the genus Actinomadura

  • Zhiwei Zhang,
  • Tao Zhou,
  • Taehui Yang,
  • Keisuke Fukaya,
  • Enjuro Harunari,
  • Shun Saito,
  • Katsuhisa Yamada,
  • Chiaki Imada,
  • Daisuke Urabe and
  • Yasuhiro Igarashi

Beilstein J. Org. Chem. 2021, 17, 2194–2202, doi:10.3762/bjoc.17.141

Graphical Abstract
  • equipped with a diode array detector was used for analysis and purification. The computational study was performed using MacroModel implemented in the Maestro 12.3 software package [27] and the Gaussian16, Revision C.01 program [28]. A part of these computations was conducted using the SuperComputer System
  • , Institute for Chemical Research, Kyoto University. Molecular structures were visualized using Maestro 12.3 software package. ECD spectra were visualized using GaussView 6.0.16 and Microsoft Excel 2019. Microorganism Actinomadura sp. AKA43 was isolated from a sea water sample collected from Sagami Bay at a
PDF
Album
Supp Info
Full Research Paper
Published 27 Aug 2021

Volatile emission and biosynthesis in endophytic fungi colonizing black poplar leaves

  • Christin Walther,
  • Pamela Baumann,
  • Katrin Luck,
  • Beate Rothe,
  • Peter H. W. Biedermann,
  • Jonathan Gershenzon,
  • Tobias G. Köllner and
  • Sybille B. Unsicker

Beilstein J. Org. Chem. 2021, 17, 1698–1711, doi:10.3762/bjoc.17.118

Graphical Abstract
  • . Identification and heterologous expression of terpene synthase genes To identify putative terpene synthases, a TBLASTN analysis with Aspergillus terreus aristolochene synthase (pdb 20A6) as query and the de novo transcriptome of Cladosporium sp. as a template was performed using the software BioEdit 7.0.9.0 [88
PDF
Album
Supp Info
Full Research Paper
Published 22 Jul 2021

Synthesis of 1-indolyl-3,5,8-substituted γ-carbolines: one-pot solvent-free protocol and biological evaluation

  • Premansh Dudhe,
  • Mena Asha Krishnan,
  • Kratika Yadav,
  • Diptendu Roy,
  • Krishnan Venkatasubbaiah,
  • Biswarup Pathak and
  • Venkatesh Chelvam

Beilstein J. Org. Chem. 2021, 17, 1453–1463, doi:10.3762/bjoc.17.101

Graphical Abstract
  • Software, San Diego, CA). HeLa cell uptake study of γ-carboline 3ac A live-cell imaging experiment was performed with HeLa cells. The HeLa cells were placed in a 4-well confocal dish (cell count ≈ 100 cells per well) and incubated for 48 h at 37 °C under 5% CO2. After 3 h of incubation with carboline
PDF
Album
Supp Info
Letter
Published 17 Jun 2021

Antiviral therapy in shrimp through plant virus VLP containing VP28 dsRNA against WSSV

  • Santiago Ramos-Carreño,
  • Ivone Giffard-Mena,
  • Jose N. Zamudio-Ocadiz,
  • Alfredo Nuñez-Rivera,
  • Ricardo Valencia-Yañez,
  • Jaime Ruiz-Garcia,
  • Maria Teresa Viana and
  • Ruben D. Cadena-Nava

Beilstein J. Org. Chem. 2021, 17, 1360–1373, doi:10.3762/bjoc.17.95

Graphical Abstract
  • electron microscope equipped with a digital camera operated at 200 keV. The size of the VLPs was measured using the ImageJ (U.S. NIH) software from digital recorded TEM images. Shrimp and rearing conditions. P. vannamei postlarvae (PL) were grown in 2,500 L circular tanks containing seawater (34 ppt
  • concentration range of the standard curve was 3.9 × 109 to 3.9 × 104 copies/ng. The ABI StepOnePlus v2.0 sequence detection system software (Applied Biosystems, USA) was used. Amplification reactions included all shrimp were analyzed (alive, dying and dead) from each experimental group. The viral load of WSSV
  • with the antiviral therapy was evaluated through the survival and mean lethal time (LT50) [52]. A Log-Rank (Mantel–Cox) test was used to analyze the Kaplan–Meier survival curves generated with the GraphPad Prism version 5.01 software (San Diego California USA). In all cases, a value of p < 0.05 was
PDF
Album
Supp Info
Full Research Paper
Published 01 Jun 2021

Photoinduced post-modification of graphitic carbon nitride-embedded hydrogels: synthesis of 'hydrophobic hydrogels' and pore substructuring

  • Cansu Esen and
  • Baris Kumru

Beilstein J. Org. Chem. 2021, 17, 1323–1334, doi:10.3762/bjoc.17.92

Graphical Abstract
  • contact angle measurement was performed using a Krüss contact angle measuring system G10 and recorded via Krüss official software. The sample with ideally flat surface is placed in front of a camera which records the water drop on the surface and estimates the angle between water droplet and surface. This
PDF
Album
Supp Info
Full Research Paper
Published 21 May 2021

A new glance at the chemosphere of macroalgal–bacterial interactions: In situ profiling of metabolites in symbiosis by mass spectrometry

  • Marine Vallet,
  • Filip Kaftan,
  • Veit Grabe,
  • Fatemeh Ghaderiardakani,
  • Simona Fenizia,
  • Aleš Svatoš,
  • Georg Pohnert and
  • Thomas Wichard

Beilstein J. Org. Chem. 2021, 17, 1313–1322, doi:10.3762/bjoc.17.91

Graphical Abstract
  • shot−1) within the laser frequency of 60 Hz. MS spectra were acquired in a mass range from m/z 100 to m/z 1000 with a resolving power of 280000. Pseudo ion intensity maps of selected m/z values were generated using the Mirion V3 software package with an m/z width of 0.01 u. In the profiling mode, the
  • acquired in MSI mode were collected with Xcalibur software version 2.8 SP1 Build 2806 (Thermo Fisher Scientific, Germany) while the acquisition of spatial scans, pre-defined in the x- and y-direction as rectangular sample regions, was controlled by the MCP (Master Control Program, TransMIT GmbH, Giessen
PDF
Album
Supp Info
Full Research Paper
Published 19 May 2021

Structural effects of meso-halogenation on porphyrins

  • Keith J. Flanagan,
  • Maximilian Paradiz Dominguez,
  • Zoi Melissari,
  • Hans-Georg Eckhardt,
  • René M. Williams,
  • Dáire Gibbons,
  • Caroline Prior,
  • Gemma M. Locke,
  • Alina Meindl,
  • Aoife A. Ryan and
  • Mathias O. Senge

Beilstein J. Org. Chem. 2021, 17, 1149–1170, doi:10.3762/bjoc.17.88

Graphical Abstract
  • device. Data were collected by using omega and phi scans and were corrected for Lorentz and polarization effects by using the APEX software suite [60][61][62][63]. Using Olex2, the structure was solved with the XS or XT structure
PDF
Album
Supp Info
Full Research Paper
Published 14 May 2021

Synthesis of 10-O-aryl-substituted berberine derivatives by Chan–Evans–Lam coupling and investigation of their DNA-binding properties

  • Peter Jonas Wickhorst,
  • Mathilda Blachnik,
  • Denisa Lagumdzija and
  • Heiko Ihmels

Beilstein J. Org. Chem. 2021, 17, 991–1000, doi:10.3762/bjoc.17.81

Graphical Abstract
  • . Emission spectra: Varian Cary Eclipse spectrophotometer in quartz cells (10 mm × 4 mm) at 20 °C. NMR spectra: Jeol ECZ 500 (1H: 500 MHz, 13C: 125 MHz) at 25 °C; processed with MestReNova software and referenced to the solvent [δ(DMSO-d5): 1H = 2.50 ppm, 13C: δ = 39.5 ppm, δ(CHCl3): 1H = 7.26 ppm, 13C: δ
PDF
Album
Supp Info
Full Research Paper
Published 04 May 2021

Enhanced target cell specificity and uptake of lipid nanoparticles using RNA aptamers and peptides

  • Roslyn M. Ray,
  • Anders Højgaard Hansen,
  • Maria Taskova,
  • Bernhard Jandl,
  • Jonas Hansen,
  • Citra Soemardy,
  • Kevin V. Morris and
  • Kira Astakhova

Beilstein J. Org. Chem. 2021, 17, 891–907, doi:10.3762/bjoc.17.75

Graphical Abstract
  • macrophages were 100% positive for Cy5. Additionally, using QuPath analysis software, we determined the Cy5 MFI for each image. Interestingly, we found that the LNP A-1 and the LNP G-3 had higher MFI values in all the donors assessed compared to the Tat and T7 counterparts (Figure 4C). Further, we found that
  • Concentration and size of LNPs with and without peptides were additionally confirmed using the NanoSight NS300 device (Malvern Panalytical, UK) with the NTA software (Version 3.44, Malvern Panalytical, UK). Samples were run at a 1:1000 dilution, with three technical replicates per sample. A blue 488 nm laser
  • Zeiss AxioCam 503 color camera (Carl Zeiss Microscopy GmbH, Germany). Images were processed using ZEN blue software (Version 2.3, Carl Zeiss Microscopy GmbH, Germany) and merged using ImageJ Version 1.53a (Wayne Rasband, NIH, USA). To assess uptake of the LNPs in primary macrophages, samples were washed
PDF
Album
Supp Info
Full Research Paper
Published 26 Apr 2021

Simulating the enzymes of ganglioside biosynthesis with Glycologue

  • Andrew G. McDonald and
  • Gavin P. Davey

Beilstein J. Org. Chem. 2021, 17, 739–748, doi:10.3762/bjoc.17.64

Graphical Abstract
  • ], Tellurium [39], or other modelling software supporting this format. Glycan structures can be imported or exported as GlycoCT [40], and exported as Linear Code [41] or IUPAC condensed linear formats. Sets of structures can be downloaded as CSV or GlycoCT. A key function of Glycologue is the ability to
  • improve upon. Nevertheless, we have shown that the knockouts are able to reproduce the distinct species-specific features and disease states arising from congenital defects of ganglioside biosynthesis. Kinetic models based on the networks described here can be generated in modelling software, using the
PDF
Album
Full Research Paper
Published 23 Mar 2021

Menthyl esterification allows chiral resolution for the synthesis of artificial glutamate analogs

  • Kenji Morokuma,
  • Shuntaro Tsukamoto,
  • Kyosuke Mori,
  • Kei Miyako,
  • Ryuichi Sakai,
  • Raku Irie and
  • Masato Oikawa

Beilstein J. Org. Chem. 2021, 17, 540–550, doi:10.3762/bjoc.17.48

Graphical Abstract
  • (Figure 10), is therefore, of interest [5], and the synthesis is also underway in our laboratory. Experimental Procedures for all chemical syntheses are described in Supporting Information File 1. Molecular modeling The CONFLEX calculations were performed using BARISTA software (Version 1.2.2.22, Conflex
PDF
Album
Supp Info
Full Research Paper
Published 24 Feb 2021

Mesoionic tetrazolium-5-aminides: Synthesis, molecular and crystal structures, UV–vis spectra, and DFT calculations

  • Vladislav A. Budevich,
  • Sergei V. Voitekhovich,
  • Alexander V. Zuraev,
  • Vadim E. Matulis,
  • Vitaly E. Matulis,
  • Alexander S. Lyakhov,
  • Ludmila S. Ivashkevich and
  • Oleg A. Ivashkevich

Beilstein J. Org. Chem. 2021, 17, 385–395, doi:10.3762/bjoc.17.34

Graphical Abstract
  • , methanol, water. Solvation effects were considered using the SMD [40] model in terms of Linear Response scheme [41]. The analysis of charge transfer during S0→S1 transition was carried out by using the Multiwfn software [36]. The NBO analysis and MESP calculations were performed using the B3LYP/6-31G(d
PDF
Album
Supp Info
Full Research Paper
Published 08 Feb 2021

Annulation of a 1,3-dithiole ring to a sterically hindered o-quinone core. Novel ditopic redox-active ligands

  • Sergey V. Norkov,
  • Anton V. Cherkasov,
  • Andrey S. Shavyrin,
  • Maxim V. Arsenyev,
  • Viacheslav A. Kuropatov and
  • Vladimir K. Cherkasov

Beilstein J. Org. Chem. 2021, 17, 273–282, doi:10.3762/bjoc.17.26

Graphical Abstract
  • [52] and CrysAlisPro [53] software packages. The structures were solved by direct methods and were refined by full-matrix least squares on F2 for all data using SHELX [54]. SADABS [55] and CrysAlisPro were used to perform the absorption corrections. All non-hydrogen atoms in 6a–d and 7–9 were found
PDF
Album
Supp Info
Full Research Paper
Published 27 Jan 2021

Multiswitchable photoacid–hydroxyflavylium–polyelectrolyte nano-assemblies

  • Alexander Zika and
  • Franziska Gröhn

Beilstein J. Org. Chem. 2021, 17, 166–185, doi:10.3762/bjoc.17.17

Graphical Abstract
  • MicroCal ITC data analysis software for Origin 7.0. Top: pelargonidin cation (Flavy) and network of chemical reactions; bottom: corresponding UV–vis spectra of the different states of Flavy. Characterization of Flavy: a) 1H NMR spectrum at pH 7.0 (form A) before and after irradiation; b) 13C NMR spectrum
PDF
Album
Supp Info
Full Research Paper
Published 19 Jan 2021

Direct synthesis of anomeric tetrazolyl iminosugars from sugar-derived lactams

  • Michał M. Więcław and
  • Bartłomiej Furman

Beilstein J. Org. Chem. 2021, 17, 115–123, doi:10.3762/bjoc.17.12

Graphical Abstract
  • an attempt at resolving this problem by means of the electronic circular dichroism (ECD) technique. We recorded an ECD spectrum of both compounds and compared it with simulated spectra, generated for both possible diastereomers (2-(R) and 2-(S)) using computational chemistry software. Unfortunately
  • calculations were performed on a simplified model to provisionally validate this proposed mechanism. The geometry of the intermediate species were optimized with Gaussian 09 software [44], using the B3LYP/LANL2DZ theory level for Zr and B3LYP/6-31G(d,p) for other atoms, with GD3 empirical dispersion correction
  • . The optimization was followed by a single-point energy calculation using the larger basis set Def2TZVP with a PCM solvatation model for THF, as implemented in the Gaussian software. Energy values reported are a sum of electronic and zero-point energies. Scheme 8 shows possible pathways for the
PDF
Album
Supp Info
Full Research Paper
Published 13 Jan 2021

Control over size, shape, and photonics of self-assembled organic nanocrystals

  • Chen Shahar,
  • Yaron Tidhar,
  • Yunmin Jung,
  • Haim Weissman,
  • Sidney R. Cohen,
  • Ronit Bitton,
  • Iddo Pinkas,
  • Gilad Haran and
  • Boris Rybtchinski

Beilstein J. Org. Chem. 2021, 17, 42–51, doi:10.3762/bjoc.17.5

Graphical Abstract
  • . The light is normally dispersed by a 300 gr/mm grating onto a fast CCD camera (Andor Newton DU-970N-UV, operating at 1,000 spectra per second using "crop mode"). The whole setup is controlled by the National Instruments LabView software. A variable neutral-density filter was employed to adjust the
PDF
Album
Supp Info
Full Research Paper
Published 06 Jan 2021

Molecular basis for protein–protein interactions

  • Brandon Charles Seychell and
  • Tobias Beck

Beilstein J. Org. Chem. 2021, 17, 1–10, doi:10.3762/bjoc.17.1

Graphical Abstract
  • analysis software and automation in liquid chromatography–mass spectrometry over the past decade made HDXMS an increasingly attractive tool for biochemists. In HDXMS, changes in the mass associated with the isotopic exchange between amide hydrogen atoms and surrounding deuterated solvent are measured. The
  • painting. However, even though HDXMS is a very reproducible and straightforward method (albeit the experiment has to be carefully and properly performed), data analysis, even with recent software automation, is the major limitation as the interpretation requires a certain level of expertise. Biophysical
PDF
Album
Review
Published 04 Jan 2021

Semiautomated glycoproteomics data analysis workflow for maximized glycopeptide identification and reliable quantification

  • Steffen Lippold,
  • Arnoud H. de Ru,
  • Jan Nouta,
  • Peter A. van Veelen,
  • Magnus Palmblad,
  • Manfred Wuhrer and
  • Noortje de Haan

Beilstein J. Org. Chem. 2020, 16, 3038–3051, doi:10.3762/bjoc.16.253

Graphical Abstract
  • aided by the Byonic software. Additional MS1-based glycopeptide identification relying on accurate mass and retention time differences using GlycopeptideGraphMS considerably expanded the set of confidently annotated glycopeptides. For glycopeptide quantification, the performance of LaCyTools was
  • automated processing of several IgA glycopeptides. Finally, this study presents a semiautomated workflow for reliable glycoproteomic data analysis by the combination of software packages for MS/MS- and MS1-based glycopeptide identification as well as the integration of analyte quality control and
  • /MS-based scoring software tools such as Byonic [14] are frequently used for glycopeptide identification [12]. Recently, software tools were developed that are based on the retention time (RT) characteristics and accurate mass differences of glycopeptide MS1 signals in RPLC–MS [10][15]. These tools
PDF
Album
Supp Info
Full Research Paper
Published 11 Dec 2020

Chiral anion recognition using calix[4]arene-based ureido receptors in a 1,3-alternate conformation

  • Tereza Horáčková,
  • Jan Budka,
  • Vaclav Eigner,
  • Wen-Sheng Chung,
  • Petra Cuřínová and
  • Pavel Lhoták

Beilstein J. Org. Chem. 2020, 16, 2999–3007, doi:10.3762/bjoc.16.249

Graphical Abstract
  • isotherms obtained from the complexation-induced chemical shift (CIS) values of urea NH protons or aromatic CH signals (Figure 5) [50][51][52]. The nonlinear curve-fitting of the experimental data was performed using the freely available software Bindfit [53]. The stoichiometry of the complexes was
PDF
Album
Supp Info
Full Research Paper
Published 07 Dec 2020

Secondary metabolites of Bacillus subtilis impact the assembly of soil-derived semisynthetic bacterial communities

  • Heiko T. Kiesewalter,
  • Carlos N. Lozano-Andrade,
  • Mikael L. Strube and
  • Ákos T. Kovács

Beilstein J. Org. Chem. 2020, 16, 2983–2998, doi:10.3762/bjoc.16.248

Graphical Abstract
  • generated with FastTree 2 from the representative sequences [71][72][73]. Relative species abundance and phylogenetic diversity analyses QIIME 2 artefacts were imported into the R software (4.0.2) with the R package qiime2R, and further analyses were conducted in the R package phyloseq [74][75][76]. The
PDF
Album
Supp Info
Full Research Paper
Published 04 Dec 2020

Controlled decomposition of SF6 by electrochemical reduction

  • Sébastien Bouvet,
  • Bruce Pégot,
  • Stéphane Sengmany,
  • Erwan Le Gall,
  • Eric Léonel,
  • Anne-Marie Goncalves and
  • Emmanuel Magnier

Beilstein J. Org. Chem. 2020, 16, 2948–2953, doi:10.3762/bjoc.16.244

Graphical Abstract
  • Parstat 2273 potentiostat was also used with its internal «Powersuite» software. For all cyclic voltammetries, the conventional representation of anodic currents is reported as positive values and cathodic currents as negative values. SF6 electrolysis was performed in acetonitrile with a constant
PDF
Album
Full Research Paper
Published 01 Dec 2020

One-pot multicomponent green Hantzsch synthesis of 1,2-dihydropyridine derivatives with antiproliferative activity

  • Giovanna Bosica,
  • Kaylie Demanuele,
  • José M. Padrón and
  • Adrián Puerta

Beilstein J. Org. Chem. 2020, 16, 2862–2869, doi:10.3762/bjoc.16.235

Graphical Abstract
  • mass spectrometer. The software used was ThermoXcalibur 2.2 SP1.48. The XRF spectroscopy analysis of the catalyst was performed using a Bruker S2 Ranger®. Catalyst preparation The method previously reported by Zhu et al. was used to prepare several supported heteropoly acids (silicotungstic and PW) on
PDF
Album
Supp Info
Correction
Full Research Paper
Published 24 Nov 2020
Other Beilstein-Institut Open Science Activities