Search results

Search for "Fresnel zone plate" in Full Text gives 4 result(s) in Beilstein Journal of Nanotechnology.

Comparative study on 3D morphologies of delignified, single tracheids and fibers of five wood species

  • Helen Gorges,
  • Felicitas von Usslar,
  • Cordt Zollfrank,
  • Silja Flenner,
  • Imke Greving,
  • Martin Müller,
  • Clemens F. Schaber,
  • Chuchu Li and
  • Stanislav N. Gorb

Beilstein J. Nanotechnol. 2026, 17, 239–250, doi:10.3762/bjnano.17.16

Graphical Abstract
  • , Pdet = 6.5 µm pixel size, 2048 × 2048 pixel, 16 bit image depth) with a 10 µm Gadox scintillator was used as the detector. For high-contrast and low-dose imaging, holotomography was applied as the phase contrast technique. Here, a gold Fresnel zone plate with a diameter of 300 µm was used [30]. By
PDF
Album
Supp Info
Full Research Paper
Published 04 Feb 2026

Beyond the bilayer: multilayered hygroscopic actuation in pine cone scales

  • Kim Ulrich,
  • Max David Mylo,
  • Tom Masselter,
  • Fabian Scheckenbach,
  • Sophia Fischerbauer,
  • Martin Nopens,
  • Silja Flenner,
  • Imke Greving,
  • Linnea Hesse and
  • Thomas Speck

Beilstein J. Nanotechnol. 2025, 16, 1695–1710, doi:10.3762/bjnano.16.119

Graphical Abstract
  • imaging beamline P05 operated by Helmholtz-Zentrum Hereon at PETRA III (DESY Deutsches Elektronen Synchrotron, Hamburg, Germany). Phase contrast-based near-field holotomography was used to image our samples, utilizing a 300 µm gold Fresnel zone plate to focus the monochromatic beam with an energy of 11
PDF
Album
Supp Info
Full Research Paper
Published 29 Sep 2025

High-throughput synthesis of modified Fresnel zone plate arrays via ion beam lithography

  • Kahraman Keskinbora,
  • Umut Tunca Sanli,
  • Margarita Baluktsian,
  • Corinne Grévent,
  • Markus Weigand and
  • Gisela Schütz

Beilstein J. Nanotechnol. 2018, 9, 2049–2056, doi:10.3762/bjnano.9.194

Graphical Abstract
  • ) radiation; focused ion beam (FIB); Fresnel zone plate; ion beam lithography (IBL); nanopatterning; soft X-rays; Introduction Requirements for focusing elements that work at extreme ultraviolet (EUV) and soft X-ray (SXR) energies are very different from those of the more familiar ultraviolet, visible or
PDF
Album
Supp Info
Full Research Paper
Published 25 Jul 2018

Electron-beam induced deposition and autocatalytic decomposition of Co(CO)3NO

  • Florian Vollnhals,
  • Martin Drost,
  • Fan Tu,
  • Esther Carrasco,
  • Andreas Späth,
  • Rainer H. Fink,
  • Hans-Peter Steinrück and
  • Hubertus Marbach

Beilstein J. Nanotechnol. 2014, 5, 1175–1185, doi:10.3762/bjnano.5.129

Graphical Abstract
  • , Poland. STXM experiments were performed at the PolLux beamline at the Swiss Light Source (SLS), Paul Scherrer Institut, Villigen (CH) [28]. The standard STXM setup uses high brilliance synchrotron radiation light that is focused on the sample by a Fresnel zone plate. The sample is raster-scanned with
PDF
Album
Supp Info
Full Research Paper
Published 30 Jul 2014
Other Beilstein-Institut Open Science Activities