Search results

Search for "electrospray" in Full Text gives 183 result(s) in Beilstein Journal of Organic Chemistry.

Molecular recognition of organic ammonium ions in solution using synthetic receptors

  • Andreas Späth and
  • Burkhard König

Beilstein J. Org. Chem. 2010, 6, No. 32, doi:10.3762/bjoc.6.32

Graphical Abstract
PDF
Album
Review
Published 06 Apr 2010

Templated versus non-templated synthesis of benzo-21-crown-7 and the influence of substituents on its complexing properties

  • Wei Jiang and
  • Christoph A. Schalley

Beilstein J. Org. Chem. 2010, 6, No. 14, doi:10.3762/bjoc.6.14

Graphical Abstract
  • coupling constants (J) are in Hertz. The following abbreviations were used for signal multiplicities: s, singlet; d, doublet; t triplet; m, multiplet. Electrospray-ionization time-of-flight high-resolution mass spectrometry (ESI-TOF-HRMS) experiments were conducted on an Agilent 6210 ESI-TOF, Agilent
  • Technologies and a Varian/IonSpec QFT-7 FTICR (Fourier-transform ion-cyclotron-resonance) mass spectrometer equipped with a superconducting 7 Tesla magnet and a micromass Z-spray Electrospray-ionization (ESI) ion source utilizing a stainless steel capillary with a 0.75 mm inner diameter. 2-{2-[2-(2-{2-[2-(2
PDF
Album
Supp Info
Full Research Paper
Published 11 Feb 2010

Synthesis of phosphonate and phostone analogues of ribose-1-phosphates

  • Pitak Nasomjai,
  • David O'Hagan and
  • Alexandra M. Z. Slawin

Beilstein J. Org. Chem. 2009, 5, No. 37, doi:10.3762/bjoc.5.37

Graphical Abstract
  • . Infra red (IR) spectra were recorded on Nicolet Avatar 360 FT-IR. High resolution mass spectrometry (HRMS) was carried out using a Micromass LCT (Manchester, UK) mass spectrometer with electrospray ionization (ESI) operating in positive and negative modes. Optical rotations were measured on Perkin-Elmer
PDF
Album
Supp Info
Full Research Paper
Published 27 Jul 2009

Synthesis of rigidified flavin–guanidinium ion conjugates and investigation of their photocatalytic properties

  • Harald Schmaderer,
  • Mouchumi Bhuyan and
  • Burkhard König

Beilstein J. Org. Chem. 2009, 5, No. 26, doi:10.3762/bjoc.5.26

Graphical Abstract
  • 35–70 μm, 60 Å from Acros. NMR spectra were recorded at a Bruker Avance 300 spectrometer (300 MHz) or at a Bruker Avance 600 spectrometer (600 MHz). Electrospray ionisation (ES-MS) mass spectra were measured on ThermoQuest Finnigan TSQ 7000 spectrometer. High resolution mass spectrometry (HRMS) was
PDF
Album
Supp Info
Full Research Paper
Published 28 May 2009

Synthesis of methylenebisamides using CC- or DCMT- activated DMSO

  • Qiang Wang,
  • Lili Sun,
  • Yu Jiang and
  • Chunbao Li

Beilstein J. Org. Chem. 2008, 4, No. 51, doi:10.3762/bjoc.4.51

Graphical Abstract
  • DMSO-d6 or CDCl3 (13C). Mass spectra were obtained using an LCQ Advantage MAX ion trap mass spectrometer equipped with electrospray ionization (ESI) ion source or a Thermo Finnigan TRACE-DSQ spectrometer. Elemental analyses for C, H and N were performed on a Yanaco CHNCORNER MF-3 elemental analyzer
PDF
Album
Supp Info
Full Research Paper
Published 15 Dec 2008

Synthesis of imidazol- 1-yl-acetic acid hydrochloride: A key intermediate for zoledronic acid

  • Santosh Kumar Singh,
  • Narendra Manne,
  • Purna Chandra Ray and
  • Manojit Pal

Beilstein J. Org. Chem. 2008, 4, No. 42, doi:10.3762/bjoc.4.42

Graphical Abstract
  • Avance 300 spectrometer (300 MHz). Electrospray (ES+) mass spectra were acquired on an ion trap mass spectrometer. Preparation of imidazol-1-yl-acetic acid tert-butyl ester (2) To a solution of imidazole (10.0 g, 0.15 mol) in ethyl acetate (160 mL) was added powdered K2CO3 (29.0 g, 0.21 mol) followed by
PDF
Album
Supp Info
Full Research Paper
Published 17 Nov 2008

The first preparative solution phase synthesis of melanotan II

  • Vladimir V. Ryakhovsky,
  • Georgy A. Khachiyan,
  • Nina F. Kosovova,
  • Elena F. Isamiddinova and
  • Andrey S. Ivanov

Beilstein J. Org. Chem. 2008, 4, No. 39, doi:10.3762/bjoc.4.39

Graphical Abstract
  • synthesized product and melanotan II purchased from a commercial source. Electrospray injection mass spectrometry of both samples demonstrated two characteristic peaks with m/z 512 and 1024, corresponding to [M+2H]2+ and [M+H]+ respectively. Conclusion In conclusion, we have developed the first solution phase
PDF
Album
Full Research Paper
Published 30 Oct 2008

Synthesis of (S)-1-(2-chloroacetyl)pyrrolidine- 2-carbonitrile: A key intermediate for dipeptidyl peptidase IV inhibitors

  • Santosh K. Singh,
  • Narendra Manne and
  • Manojit Pal

Beilstein J. Org. Chem. 2008, 4, No. 20, doi:10.3762/bjoc.4.20

Graphical Abstract
  • applications in the design and synthesis of novel DPP-IV inhibitors for the potential treatment of type-II diabetes. Experimental General methods All the compounds synthesized were characterized by NMR, IR and MS spectra. 1H NMR spectra were recorded on a Bruker Avance 300 spectrometer (300 MHz). Electrospray
PDF
Album
Supp Info
Full Research Paper
Published 12 Jun 2008